For example a single wall stove pipe requires 18 inches of clearance from ceilings or walls.
Triple wall stove pipe clearance.
As listed where shown in the table above means that the acceptable fire clearance distances for those chimney types must match or comply with the manufacturer s instructions.
Many think stovepipe can run from the wood stove right up through the ceiling and roof.
This boosts stove efficiency by exhausting hot flue gases easily and efficiently.
Once these clearances are met you must convert your stove pipe to class a chimney pipe for proper venting of your stove.
Save up to.
Listing double and triple wall insulated pipe is listed as class a vent pipe and must meet either ul standard 103 or 103ht.
Our class a tiple wall chimney systems stay cool on the outside while providing a hot draft on the inside.
Chimney pipe also is made in two types double wall and triple wall.
Duravent pipe 3 wall close clearance kit 6dvl kvp.
Notes to the metal chimney fire clearance table above.
Class a triple wall chimney systems are designed for easy installation feature a fire safe design to protect both the chimney the building.
The ceramic blanket insulation is held securely in position eliminating hot spots common with loose.
Stove pipe is made in single and double wall versions.
Double wall stove pipe on the other hand requires only 8 inches of clearance from the ceiling and 6 inches from a wall.
A class a chimney pipe requires less clearance than a single or double wall stovepipe which is only intended for use within the same room as the stove.
This triple wall chimney features two insulating layers ceramic blanket plus air space.
Most of the double wall stove pipe allows for 6 clearance from wall combustibles and 8 from ceiling combustibles.
Duravent duraplus 36 in.
Ul standard 103 requires pipe capable of safety operating with an internal temperature of 1 000.
Materials and construction 016 430 stainless steel outer wall or 018 galvanized steel outer wall.
0 0 was save.
018 aluminized steel intermediate liner.
Those clearance spacings are normally found in at least two locations.
Using a heat shield on a single wall stovepipe allows you to reduce the clearances from 18 to 6 to the wall and 9 to the ceiling.
Product rating is 5.
016 430 stainless.
Duraplus is designed to stay cool on the outside to provide a hot draft on the inside to boost stove efficiency and to provide for a fire safe design that protects both the chimney and the building.
The installation instructions for the specific flue vent connector or metal.
Triple wall stainless steel chimney pipe 6dp 36ss.